CAN out – CAN output mailbox
Table of Contents
The CAN output mailbox block allows sending CAN messages with up to 8 bytes long payloads.
It supports two operating modes:
- On-demand mode: the user manually triggers the message transmissions.
- Periodical mode: the message is sent periodically, whether the data has been changed or not. The user can configure the transmission frequency.
Simulink block
Signal specification
- The data input signal supports a vector of data. The accepted data type is configured by
Signal typeparameter. The vector length can be configured withNumber of signalsparameter. - The second input is the send data signal. It is used to initiate a data transmission when the on-demand mode has been selected. Data is sent upon a rising edge on this signal.
Parameters
CAN address: sets the CAN output mailbox address. It also sets the CAN unique identifier of the data frame.Signal Type: defines the data type accepted in the data input (int8, uint8, int16, uint16, int32, uint32, in64, uint64, float, or double).Number of signals: sets the vector length of the data output. (from 1 to 8)Byte order: defines the byte order in which the data will be sent. Either little-endian or big-endian.Tx frequency: Sets the data transmission frequency if the periodical mode has been selected.Baud rate: configures the baud rate of the CAN bus. Baud rates up to 1 Mbit/s are supported.
Signal type and Number of signals) can not exceed 64 bits (8 bytes), which is the maximum payload of a CAN frame.PLECS block
Signal specification
- The data input signal supports a vector of data. The accepted data type is configured by
Signal typeparameter. The vector length can be configured withNumber of signalsparameter. - The second input is the send data signal. It is used to initiate a data transmission when the on-demand mode has been selected. Data is sent upon a rising edge on this signal.
Parameters
CAN address: sets the CAN output mailbox address. It also sets the CAN unique identifier of the data frame.Signal Type: defines the data type accepted in the data input (int8, uint8, int16, uint16, int32, uint32, in64, uint64, float, or double).Number of signals: sets the vector length of the data output. (from 1 to 8)Byte order: defines the byte order in which the data will be sent. Either little-endian or big-endian.Tx frequency: sets the data transmission frequency if the periodical mode has been selected.
Signal type and Number of signals) can not exceed 64 bits (8 bytes), which is the maximum payload of a CAN frame.