DAC – Analog outputs
Table of Contents
The DAC block applies a given value to one of the four analog outputs of the B-Box RCP. The corresponding hardware specifications are available in the B-Box datasheet.
Simulink block
Signal specification
The input signal is the value to apply to the analog output specified in volts (-5V to 5V). The output is saturated beyond these limits.

Standard parameters
Device ID
selects which B-Box/B-Board to address when used in a multi-device configuration.Analog output channel
selects a physical analog output channel (0 to 3)

PLECS block
Signal specification
The input signal is the value to apply to the analog output specified in volts (-5V to 5V). The output is saturated beyond these limits.

Standard parameters
Device ID
selects which B-Box/B-Board to address when used in a multi-device configuration.Analog output channel(s)
(vectorizable) selects a physical analog output channel(s) (0 to 3).